Browse
Search
2015-220-E AMS - BIRS, Inc. for new roof replacement on courthouse $134,396
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2015
>
2015-220-E AMS - BIRS, Inc. for new roof replacement on courthouse $134,396
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2016 3:29:10 PM
Creation date
5/26/2015 2:16:39 PM
Metadata
Fields
Template:
BOCC
Date
5/27/2015
Meeting Type
Work Session
Document Type
Contract
Agenda Item
Manager signed
Document Relationships
R 2015-220-E AMS - BIRS, Inc. for new roof replacement on courthouse
(Linked To)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:4E43C797-33A3-4C29-9D23-96EA82AC437C <br /> Addendum No.2-Prebid Minutes <br /> New Courthouse 1954—Sectors A,E,F,and G <br /> March 2,2015 <br /> Page 3 <br /> Existing roof system components: <br /> Single ply(EPDM) <br /> Board insulation(wood fiber, 1.5"approximately) <br /> Gypsum deck <br /> Section 015000—Temporary Facilities and Controls <br /> The Owner will furnish electricity and water required for construction. Access to electricity and <br /> water will be as designated by the Owner. All wiring needed to facilitate construction is to be <br /> temporary in nature and furnished and installed at no cost to the Owner. Upon completion of the <br /> work wiring is to be removed and service restored to its original condition. <br /> Section 017850—Warranties <br /> 5-year contractor warranty required. <br /> 20-year manufacturer warranty required. <br /> Section 024119—Selective Demolitions <br /> Remove existing roof to deck. Repair damaged areas,if any. <br /> Section 061000—Rough Carpentry <br /> New wood blocking and nailers required. <br /> Section 072120—Board Insulation <br /> Insulation system consisting of two layers (2.25" each) of polyisocyanurate board insulation. <br /> Provide tapered material in valleys of Sector A and all of Sectors E,F,and G. <br /> Overlayment board to be installed over insulation system. <br /> Delete mechanical fastening. All layers set in adhesive. <br /> Fastener pull testing NOT required. <br /> Section 075217—Polymer Modified Bituminous Membrane Roofing(Cold Applied) <br /> 2-ply system to be installed. Membrane to be installed in cold adhesive. <br /> Section 076200—Sheet metal flashing and Trim <br /> New sheet metal to include coping,counterflashing,and miscellaneous trim. <br /> VIL DRAWINGS <br /> No comments <br />
The URL can be used to link to this page
Your browser does not support the video tag.