Orange County NC Website
211 <br />Conventional Septic System Area Computation <br />Client Name: <br />Number Bedrooms: <br />Design Flow (gal /day): <br />LTAR (gal /day /ft) <br />Trench Bottom Area (ft): <br />Trench Width (ft): <br />On- center distance between trenches (ft): <br />Trench Bottom Length (ft): <br />Minimum Field Area Required (ft): <br />Minimum Field Area Required (Innovative) (ft) <br />Total Field Area Required (ft)('): <br />Total Field Area Required (Innovative) (ft)('): <br />Total Field Area Required (ft)('): <br />Total Field Area Required (Innovative) (ft)('): <br />Ennis <br />Created by: JV <br />Created on: 6/20/2001 <br />Updated on: 1/12/2014 <br />5 <br />600 (120 gal /day /bedroom, minimum 240 gal /day /dwelling) <br />0.1 <br />6000 (Design flow /LTAR) <br />3 <br />9 <br />2000 <br />18000 (Trench Bottom Length'Trench on- center distance) <br />13500 (25% reduction from above) <br />45000 (Minimum field area'2.5) <br />33750 (25% reduction from above) <br />54000 (Minimum field area'3) <br />40500 (25% reduction from above) <br />(1) Provides for reserve area and soil irregularity, 2.5 to 3 is multiplier. <br />Client Name: Ennis <br />Number Bedrooms: <br />Design Flow (gal /day): <br />LTAR (gal /day /ft) <br />Trench Bottom Area (ft): <br />Trench Width (ft): <br />On- center distance between trenches (ft): <br />Trench Bottom Length (ft): <br />Minimum Field Area Required (ft): <br />Minimum Field Area Required (Innovative) (ft) <br />Total Field Area Required (ft)('): <br />Total Field Area Required (Innovative) (ft)('): <br />Total Field Area Required (ft)('): <br />Total Field Area Required (Innovative) (ft)('): <br />5 <br />600 (120 gal /day /bedroom, minimum 240 gal /day /dwelling) <br />0.4 <br />1500 (Design flow /LTAR) <br />3 <br />9 <br />500 <br />4500 (Trench Bottom Length'Trench on- center distance) <br />3375 (25% reduction from above) <br />11250 (Minimum field area'2.5) <br />8437.5 (25% reduction from above) <br />13500 (Minimum field area'3) <br />10125 (25% reduction from above) <br />(1) Provides for reserve area and soil irregularity, 2.5 to 3 is multiplier. <br />Client Name: <br />Number Bedrooms: <br />Design Flow (gal /day): <br />LTAR (gal /day /ft) <br />Trench Bottom Area (ft): <br />Trench Width (ft): <br />On- center distance between trenches (ft): <br />Trench Bottom Length (ft): <br />Minimum Field Area Required (ft): <br />Minimum Field Area Required (Innovative) (ft) <br />Total Field Area Required (ft)('): <br />Total Field Area Required (Innovative) (ft)('): <br />Total Field Area Required (ft)('): <br />Total Field Area Required (Innovative) (ft)('): <br />Ennis <br />5 <br />600 (120 gal /day /bedroom, minimum 240 gal /day /dwelling) <br />0.25 <br />2400 (Design flow /LTAR) <br />3 <br />9 <br />800 <br />7200 (Trench Bottom Length'Trench on- center distance) <br />5400 (25% reduction from above) <br />18000 (Minimum field area'2.5) <br />13500 (25% reduction from above) <br />21600 (Minimum field area'3) <br />16200 (25% reduction from above) <br />(1) Provides for reserve area and soil irregularity, 2.5 to 3 is multiplier. <br />