Orange County NC Website
chose this area because it was located within the rural buffer, and we believed that the <br /> thoughtful zoning regulations in the rural buffer would work to preserve the rural character of <br /> Orange County. Tonight I want to express our strong opposition to a granting of a special use <br /> permit for the proposed project. I have outlined our general reasoning for opposing the project <br /> in a written statement that I submitted to staff earlier today; and since that statement overlaps <br /> with much of what previous speakers have already said, I won't cover that ground again. I <br /> would however like to address two specific deficiencies that I found in the applicant's submittal <br /> that I believe are very important. <br /> The first of these has to do with whether the soil types and compaction study <br /> requirements of the UDO have been met for the SUP submission. In section 5.9.6 C 1 of the <br /> UDO there are specific submittal requirements for solar arrays of this scale, that is utility scale <br /> solar arrays. Part C 1 states that in addition to the information required by section 2.7 the <br /> following shall be submitted as a part of the application. In submittal requirement D—there are <br /> 4 requirements listed — D reads as follows: "A soils report denoting the types of soil on the <br /> property including detail on the compaction necessary to support the proposed development." <br /> This language appears to be plain and straightforward that a soils report and a compaction <br /> study are required for submittal. I have not been able to find any documents concerning soils in <br /> the applicant submittal materials, although staff has told me—the planning staff has told me <br /> there is a soil map of some sort. I don't know what detail that map contains because I haven't <br /> see it. However, in the site plan for the development, the developers proposed to conduct a <br /> geotechnical study after approval of the SUP. A full geotechnical report should be required prior <br /> to consideration of approval of the SUP submission for the following reasons: <br /> First, this development calls for a large-scale 20 acre, 5 megawatt power installation <br /> requiring the erection of 18,354 solar panels in 966 strings. Based on the site plan drawings and <br /> the information you saw tonight these are going to be held up by relatively small supports along <br /> their length. The structures will be subject to wind shear, to soil-soaking rains and other <br /> stresses, so a full assessment of soil properties is critical in order for planning staff to fully <br /> understand the site's suitability. Such a report could well reveal soil compaction characteristics, <br /> subsurface rock features at a shallow depth - and by the way, I have rock outcrops in my yard, <br /> just a 100 or so feet away from the boundary - or other unknown but important features that <br /> would affect the Planning Staff's opinions and recommendations, and also possibly the State <br /> regulatory agency approvals. In addition, the property owners affected by this project would then <br /> have an opportunity to review and comment on the soil report, which we have not had. <br /> So I request, even though it may cost extra expense for the developers— may eat into <br /> their profits ultimately a little bit— I request that the commission require submission of a full soil <br /> test as required by the UDO before any decision is made on the SUP. <br /> The second issue that I want to touch on has to do with the serious flaws in the Binks <br /> noise impact assessment. I think these flaws invalidate this assessment. The applicants <br /> initially based their impact assessment on two documents. Could I turn on the overhead? Does <br /> someone know how to do that? So this is included in the application packet. In this view of the <br /> site the applicants showed eight, 500 kilowatt inverters scattered across the site, none of which <br /> are located particularly near to an adjacent property. The nearest one to a property along <br /> Cascade Drive would be this on, which is 200 feet away. The applicants also submitted data <br /> from an independent testing lab on the type of inverter that they propose to use—a Solaron — <br /> anyway, it's a 500 kilowatt inverter from a particular company— In that testing, the lab said that <br /> the noise produced by this inverter at 1 meter was 68 decibels. This is the data you heard <br /> earlier tonight, I believe from Mr. Wallace. However, in the current— in the site plan the <br />