Browse
Search
2014-378 Planning - J. F. Wilkerson Contracting for Morinaga America Infrastructure Improvements $747,840
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2014
>
2014-378 Planning - J. F. Wilkerson Contracting for Morinaga America Infrastructure Improvements $747,840
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2017 4:12:50 PM
Creation date
8/6/2014 2:06:17 PM
Metadata
Fields
Template:
BOCC
Date
6/17/2014
Meeting Type
Regular Meeting
Document Type
Contract
Agenda Item
6n - Mgr signed
Amount
$747,840.00
Document Relationships
R 2014-378 Planning - J. F. Wilkerson Contracting for Morinaga America Infrastructure Improvements
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2014
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
450
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
All pipe shall be thoroughly cleaned of earth and rubbish before being placed in <br /> ' the trench, and so kept until final completion and acceptance of the work. <br /> Every open end of the pipe shall be securely plugged when pipe laying is not in <br /> progress. <br /> ' All pipe shall be laid on lines and grades as directed by the Engineer and as <br /> shown on the Drawings. All pipe shall be placed on a firm foundation so as to <br /> ' prevent subsequent settlement, and the trenches shall be carefully excavated <br /> to the proper grade, except where rock excavation is encountered, so that it will <br /> be unnecessary to fill in under the pipe. Bell holes shall be provided for all pipe <br /> ' laying modes and special care shall be exercised in obtaining full barrel <br /> support. <br /> ' 90 Pipelines Crossina Gravel Drives. Wherever a water line crosses a gravel <br /> drive, it shall be backfilled as hereinbefore described in backfilling trenches for <br /> crossing paved roads, except the top six inches (6") shall be filled with <br /> ' thoroughly compacted aggregate base course (ABC). <br /> 10. Pipe Laying-Cast Iron Water Main. The installation of cast iron pipe for <br /> water main shall be performed in accordance with the appropriate sections and <br /> subsections of AWWA C-600. Minimum cover for water mains 10" diameter <br /> and smaller shall be 3 feet. Minimum cover for water mains 12" and larger <br /> shall be 4 feet. Pipe shall be installed as shown on the Plans and as directed <br /> by the Engineer. : <br /> t <br /> Handling of pipe and accessories shall at all times be done in such a manner <br /> ' as to prevent damage to lining of body. All pipe, fittings, valves and hydrants <br /> shall be lowered into the trench by approved methods. Under no <br /> circumstances shall pipe or accessories be dropped or dumped into the trench. <br /> Pipe shall be swabbed clean before it is laid and any pipe which cannot be <br /> cleaned with a swab shall be removed and cleaned with suitable apparatus. <br /> ' Any pipe showing evidence of oil, tar or grease shall be permanently marked <br /> and removed from the job and shall not be returned until it has been cleaned to <br /> the satisfaction of the Engineer. <br /> ' Laying of pipe shall be done in accordance with section 7 of AWWA C-600, <br /> with care being taken to provide uniform bearing for the pipe. The laying of <br /> ' pipe on wood or other blocking will not be permitted. Bell ends shall face <br /> direction of laying unless otherwise directed by the Engineer. For lines on an <br /> appreciable slope, the Engineer may require that bell ends face upgrade. Bell <br /> and spigot of pipe shall be thoroughly cleaned and properly lubricated where a <br /> ' mechanical joint or a "push on"type of joint is employed. <br /> ' WATER LINES: DETAILED SPECIFICATIONS FOR INSTALLATION W-5 <br /> 10/15/09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.