Orange County NC Website
Attachment#1 <br /> date: April 3 2014 <br /> from: Ron Cox <br /> subject: Addendum items Sportsplex <br /> 1.Moveable partitions to have an STC rating of 50 or higher <br /> 2. Roof drain discharge to be just above sidewalk through the low brick wall <br /> beside the sidewalk <br /> 3. Add alternate on sheet A1.1 for obscure glass is for lower lites of window wall <br /> only. <br /> 4. There should be an additional add alternate to apply translucent film to these <br /> lower lites in lieu of obscure glass. <br /> 5. Wall section detail 3/A3.2 calls for 5/8" densglas. This should be DensDeck <br /> instead <br /> 6. Owner to verify that there is enough stored matching brick for foundation wall. <br /> 7. Demo plan: Contractor to remove flooring in room 101 and 105. And where <br /> required for room 110. Owner will remove flooring in other areas that receive <br /> rubber flooring. <br /> 8. Finish Schedule: Flooring in room 110 to be Vinyl tile not rubber as shown on <br /> the finish schedule. This flooring to be installed by the Contractor. <br /> 9. Existing doors and frames may be reused if they are not damaged. <br /> Ron Cox <br /> Gc�fit. <br />