Browse
Search
Agenda - 11-12-2013 - 1
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2013
>
Agenda - 11-12-2013 - Work Session
>
Agenda - 11-12-2013 - 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2015 3:11:27 PM
Creation date
11/8/2013 2:15:22 PM
Metadata
Fields
Template:
BOCC
Date
11/12/2013
Meeting Type
Work Session
Document Type
Agenda
Agenda Item
1
Document Relationships
Minutes 11-12-2013
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Informal Resident Advisory Work Group <br />Cedar Grove Community Center <br />September 24, 2013 <br />Page 2of5 <br />52 <br />• John Thomas reviewed some of the items that had been discussed at the previous meetings <br />o The group was reminded that only 10,000 square feet of renovation has been funded. This had been <br />funded with a budget of $2,000,000 from July 1, 2013 until June 30, 2014 and that this budget included <br />design team fees, surveys, geo tech reports as well as the building construction costs. <br />• John Thomas presented the plan that had been revised as discussed at the previous meeting and reviewed the <br />changes; <br />o Option "A3" <br />• The existing Gym remains in place, the roof is not raised and the space is now called a Multi- <br />purpose Room. <br />• A folding partition is provided at the front of the stage to allow this space to be used both as a <br />stage and an exercise room. <br />• Mirrors will be provided at the rear wall of the stage to allow for the space to be used for dance <br />or exercise programs. <br />• Curtains will be provided at the front of the stage for use during performances. Roll back <br />cycloramas will be provided on the sides and back to hide the mirrors and stage wings during <br />performances. <br />• One set of existing access steps from the Multi- purpose Room to the Stage has been removed to <br />provide a storage area on the stage for exercise equipment. <br />• The architect stated that due to low water pressure issues and the expense of adding a fire pump <br />and water storage tank, a fire suppression system for the building is not feasible. Therefore, the <br />capacity of the Multi- purpose room will be restricted to a maximum of 299 people. This <br />approach will need to be coordinated and approved by the county. <br />• Handicapped access to the stage will be provided by a wheelchair lift. <br />• The existing wings remain and are mothballed. <br />• New group toilets are provided in the same location as the existing toilets but are enlarged, made <br />handicapped accessible and provided with exterior access. <br />• The exterior doors to the group toilets have been eliminated. <br />• Two toilets and a smaller storage area have been provided near the Kitchen. One of the toilets <br />opens to the exterior for park use and one opens to the Kitchen.. <br />• The existing library becomes a Multi -media Room with a computer storage area provided directly <br />of this space. <br />• A Computer networking and storage area has been provided of the Multi -media room <br />• The Facility Office has been relocated so it has an exterior window for better site supervision as <br />well as a window to the corridor for better interior supervision. <br />• Internet Cafe is provided adjacent to ceremonial front door. This space will be a more informal <br />relaxed gathering space with access to vending machines and coffee. <br />• Wireless internet is to be provided thru -out the entire building. <br />• A Conference Room is provided adjacent to Internet Cafe. <br />• The Parks and Recreation office area has been expanded and provided with a direct access to the <br />exterior of the building. <br />• The existing breezeway between the existing main building and the Dining Room is to be <br />enclosed and made into a Lobby /Corridor <br />• The Kitchen has slightly increased in size and is still provided with direct access to the Large <br />Group Meeting Room through a pass thru window with counter top and roll up door. <br />• The existing dining space is subdivided into three spaces, a Large Group Meeting Room, Small <br />Group Meeting Room and Recreation Room. <br />
The URL can be used to link to this page
Your browser does not support the video tag.