Browse
Search
Agenda - 01-29-1996
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1990's
>
1996
>
Agenda - 01-29-1996
>
Agenda - 01-29-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2013 4:52:55 PM
Creation date
10/15/2013 4:52:42 PM
Metadata
Fields
Template:
BOCC
Date
1/29/1996
Meeting Type
Schools
Document Type
Agenda
Document Relationships
Minutes - 19960129
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\1990's\1996
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DESIGN INFORMATION <br /> Work Counter Heights Standards Construction <br /> Pre-K-3 4-5 6-8 9-12 School Planning will not approve new school construc- <br /> 24"to 26"* 3011* 30" to 3611* 33"to 36" tion or school additions of type VI construction <br /> (N.C.S.B.C.) over one story. Type VI construction is <br /> * Handicapped standards for children up to age 12 strongly discouraged due to its inherent fire hazard po- <br /> must be met. tential and future limitations on expansion. <br /> Space Profiles <br /> Chalkboard Rail Heights Standards Upon request,School Planning can provide a computer- <br /> Pre-K-3 4-5 6-8 9-12 ized space profile for a given enrollment(Pre-K-5,6-8& <br /> 21"-26" 28"-30" 29"-32" 33"-36" 9-12). <br /> Plumbing Fixture Mounting Standards Ceilings <br /> Grades Height(to rim) Accessible Lay-in ceilings are most often used and are acceptable. <br /> to the Disabled Gypsum board is recommended in small spaces,low-ceil- <br /> Water Closets ing areas, toilets and dressing rooms, and unsupervised <br /> areas. Multipurpose rooms and gymnasiums should have <br /> K-3 15" 15" a cementitious fiber roof deck for proper acoustics. <br /> 4-6 15" 15" <br /> 7-12 15" 17"-19" Walls <br /> Urinals Masonry walls are preferred. Gypsum board stud walls <br /> K-3 14"-17" 14" require more maintenance. Chair rails and double layer- <br /> 4-6 20" 14" ing of sheetrock are recommended for increased durabil- <br /> 7-9 22" 17" ity. Stud walls in administration and guidance areas may <br /> 10-12 24" 17" be preferred for flexibility. <br /> Lavatories Floors <br /> K-1 24" 28" Primary classrooms should have a good grade of carpet, <br /> (24"min. knee space) since many activities take place on the floor.Resilient tile <br /> 2-6 27" 30" is recommended for other classrooms and for wet areas in <br /> 7-12 31" 34" carpeted rooms. Multipurpose rooms and gymnasiums <br /> Drinking Fountains should have resilient floors such as wood, synthetic or <br /> K-3 24" 30" high density carpet.Dance rooms should have wood floors <br /> 4-6 28" 30" that have more resilience than many gym floors. <br /> 7-12 34" 34" Carpeting is recommended in corridors for acoustical con- <br /> Showers trol. There should be a separate area of carpet at outside <br /> K-5 Boys& Girls 50"-56" 66"fixed doors so that it can be replaced easily. <br /> 48"flexible Terrazzo is often used in corridors when durability is <br /> 7-9 Boys 72" 74"fixed desired. <br /> 60"flexible <br /> 7-9 Girls 60"-66" 74"fixed Computers <br /> 60"flexible Provide cable trays,conduit and equipment rooms for a <br /> 10-12 Boys 72" 74"fixed computer network.(see"Minimum Checklist for Mechani- <br /> 60"flexible cal and Electrical Plans&Specifications; 1992,School <br /> 10-12 Girls 66' 74"fixed Planning) <br /> 60"flexible Lighting <br /> Fluorescent lighting is recommended for general light- <br /> ing.Incandescent lighting should only be used for limited <br /> accent lighting,stage lighting and special an room light- <br /> ing.Gymnasiums should use metal halide fixtures.Metal <br /> halide should be considered in other large-volume spaces. <br /> Fluorescent fixtures should have T-8 lamps&electronic ==� ° <br /> ballasts with three or four tubes,and double switching to <br /> control inside tubes separately. Fixtures in dishwashing <br /> areas,kitchens and shower rooms should be moisture re- <br /> 26 sistant. <br />
The URL can be used to link to this page
Your browser does not support the video tag.