Browse
Search
Agenda - 01-29-1996
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1990's
>
1996
>
Agenda - 01-29-1996
>
Agenda - 01-29-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2013 4:52:55 PM
Creation date
10/15/2013 4:52:42 PM
Metadata
Fields
Template:
BOCC
Date
1/29/1996
Meeting Type
Schools
Document Type
Agenda
Document Relationships
Minutes - 19960129
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\1990's\1996
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PHYSICAL ED16,1%.. <br /> Rooms Standards Comments and Recommendations <br /> Grades Spaces Square Footage <br /> K-6 Multipurpose/indoor P.E. 3,600 K-6 indoor P.E. areas should include additional square <br /> (play area) footage for an office, storage and toilets for boys and <br /> girls. Add space if a stage is included. The 6-8 grade <br /> 6-9 Gymnasium Varies gymnasium should include dressing and shower areas, <br /> 42'x 74'court+ *safety space+seating offices and some storage. Assembly and spectator use <br /> may require increased size.The 9-12 gymnasium should <br /> 9-12 Gymnasium Varies include space for two play courts,spectator seating,dress- <br /> 50'x 84'court+ *safety space+seating ing and shower areas. office areas, storage and a lobby. <br /> Additional P.E. and athletic facilities may be needed to <br /> *Safety space of 6'on each side and 8'on each end of a schedule the program in larger schools.Additional stor- <br /> basketball court is required in all cases. age may be needed for exceptional children programs. <br /> Locker and dressing rooms should be visible from P.E. <br /> 9-12 wrestling(competitive) 3,000 teachers'offices to reduce vandalism and violence. Pri- <br /> 9-12 resistive exercise(weight room) 2,000-3,000 vate shower stalls with an enclosed dressing area should <br /> Windows Standard be provided for both boys and girls. <br /> Play areas and gymnasiums must have windows or other An auxiliary gymnasium with a minimum of 3,600 sq. <br /> daylight sources to provide a minimum amount of natu- ft.is recommended for schools with 1,000 and more stu- <br /> ral lighting. dents. <br /> Lighting Standards A resilient floor finish such as high-density gym carpet <br /> Spaces Footcandles is recommended for wrestling rooms and resistive exer- <br /> Exercise areas,gymnasiums and locker rooms 30 cise rooms.Resistive exercise and wrestling rooms must <br /> Athletic events 50 be located in an area accessible to both genders. <br /> Ceiling Heights Standards Windows in physical activity areas should be located to <br /> Grades Ceiling Height prevent glare.Locker rooms should have a daylight source <br /> K-6 15'-0" for safety. <br /> 6-9 20'-0" <br /> 9-12 20'-0"to 24'-0" Lay out resistive exercise rooms with T-0"clear around <br /> extended equipment parts or limbs and allow additional <br /> Support areas under 850 sq. ft. 9'-4" width for spotters and circulation. <br /> Dressing,showers,etc. 10'-0" <br /> P.E.and athletic teaching areas Guardrails must be provided at the rear and at open ends <br /> (weight,team.wrestling rooms) 12'-0" of elevated seating facilities. including tip-and-roll <br /> bleachers, where the seating height exceeds 30". <br /> Twenty percent(20%)of the gymnasium and playroom <br /> Other Planning Resources: ceiling may be lower,provided the North Carolina State <br /> a Fieldho Building Code minimum is met.All playrooms and gym- <br /> • 198P 7 Division of School Planning, nasiums are teaching stations and require good acous- <br /> tics.The ceiling is the best area to treat acoustically. <br /> Swimming pools are a local option that is recommended. <br /> An instructional pool can serve many programs and the <br /> design should meet the requirements of the educational <br /> specifications.It is recommended that a competition pool <br /> be 50 meters in length with 6 lanes. Community use of <br /> the multipurpose room. gymnasium or swimming pool <br /> may require additional design considerations. <br /> 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.