Browse
Search
Agenda - 03-19-2013 - 5g
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2013
>
Agenda - 03-19-2013 - Regular Mtg.
>
Agenda - 03-19-2013 - 5g
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2015 11:09:43 AM
Creation date
3/15/2013 9:55:35 AM
Metadata
Fields
Template:
BOCC
Date
3/19/2013
Meeting Type
Regular Meeting
Document Type
Agenda
Agenda Item
5g
Document Relationships
Minutes 03-19-2013
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2013
ORD-2013-011 Ordinance approving Budget Amendment #8-B for the purchase/replacement of Public Safety Consoles
(Linked From)
Path:
\Board of County Commissioners\Ordinances\Ordinance 2010-2019\2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT SPEC SHEET <br />MCC 7500 IP DISPATCH CONSOLE <br />SPECIFICATIONS <br />System Compatibility <br />ASTRO '5 25 System and PremierOne'a CAD Application <br />Vocoder Algorithms supported <br />AMBE, IMBE, ACELP, G.728, G.711 <br />Encryption Algorithms supported <br />AES (256 bit), DES-OFB, DVI-XL, ADP (Advanced Digital Privacy), DES-XL, DVP-XL <br />Monitor requirements <br />With Mouse or Trackball <br />17" minimum, 20" recommended <br />Touchscreen <br />20" minimum <br />Voice Processor Module (VPM) <br />connections <br />Connector type Device <br />RJ45 One desktop microphone, eight desktop speakers, one local logging <br />recorder, one radio instant recall recorder, one console telephony instant <br />recall recorder, one external telephone set, one external paging encoder, <br />one footswitch <br />DB15 Two headset jacks connectors <br />VPM mounting options <br />EIA 19" rack mount, console furniture mount, Desktop -- supports monitor up to 80 lbs <br />VPM audio inputs and outputs <br />600 Ohm, balanced and transformer coupled (except for microphone which is 200,0 Ohm, balanced, and does not <br />use a transformer) <br />Speaker Mounting Options <br />Desktop, furniture mount, or wall mount (with bracket accessory) <br />Dispatch Console Cable Lengths <br />VPM to Speaker cable 10.1 feet (3,09 meters) standard <br />VPM to Headset Jack cable 6 feet (1.8 meters) standard <br />Headset Jack Extension cable 6 feet (1.8 meters) standard' <br />VPM to Microphone cable 10 feet (3.05 meters) standard <br />VPM to Footswitch cable 10 feet (3.05 meters) standard <br />Supported Console Site <br />Fractional T1/E1, Single T1 /E1, Multiple T1 /F1 s <br />Link types <br />fledundant and non-reclunclant versions IP site links <br />MCC 7500 Dispatch <br />Up to 60 simultaneous audio sessions per operator position <br />Console Capacities <br />Up to 60 simultaneous encryption /decryption sessions per secure capable operator position <br />Up to 3 Multi-Select groups per operator position (with up to 20 members per Multi-Select group) <br />Up to 16 Patch groups per operator position (with up to 20 members per Patch group) <br />Up to 160 resources per operator position <br />Conventional Channel Gateway <br />Rack mountable, 1 rack unit high <br />T1 R1, T2R2, T4R4, T8R8, T12R12, T1 41114 channels <br />Simple analog, MOC 1200 analog, pure digital, mixed mode (analog /digital) channels, consolettes <br />Standard density CCGWs provide interfaces for up to four analog conventional channels <br />High density CCGWs provide interfaces for up to aught analog conventional channels <br />Each analog conventional channel interface contains the following inputs and outputs <br />- 600 Ohm, balanced analog audio input -To accept radio aludio from the channel. Can be configured to support <br />AGC, OLM, or no input conditioning. <br />- 600 Ohm, balanced analog audio output - To send console transmit audio to the channel <br />* 600 Ohm, balanced analog audio output - To send console transmit and radio receive audio to a logging recorder <br />* 1 Amp, 24 VDC relay output - For relay keying of the channel <br />* Input buffer - To detect Carrier Operated Relay (CDR) closure in the channel <br />• Input buffer - To detect Line Operated Busy Light (LOBL) closure in the channel <br />- Input buffer - To detect Coded /Clear closure on an Advanced Securenet channel <br />Standard density CCGWs provide interfaces for up to four V.24 based ASTRO 25 conventional channels <br />High density CCGWs provide interfaces for up to eight V.24 based ASTRO 25 conventional channels <br />- V24 to station or comparator. No Digital Interface Unit (DIU) required. <br />Standard density CCGWs can support up to 24 conventional channels simultaneously (four analog + four V24 <br />based ASTRO 25 conventional + sixteen IP based ASTRO 25 conventional) <br />High density CCGWs can support up to 32 conventional channels simultaneously ( eight analog + eight V.24 based <br />ASTRO 25 conventional + sixteen IP based ASTRO 25 conventional) <br />
The URL can be used to link to this page
Your browser does not support the video tag.