Orange County NC Website
Proposal for Geotechnical Engineering Services Irerracon <br /> Proposed Water/Sewer Improvements a Mebane, North Carolina <br /> November 19,2012 a Terracon Proposal No. P70120505 <br /> 2.0 SCOPE OF SERVICES <br /> The primary objective of our geotechnical services will be the identifying the presence of <br /> bedrock and groundwater at the proposed directional bore and/or bore and jack locations. At <br /> your direction, we propose to perform Standard Penetration Test(SPT) Borings to a depth of 10 <br /> feet (bore and jack locations) to 20 feet (directional bore locations) below the proposed pipe <br /> invert elevation at the indicated crossing locations. We understand that the bore and jack <br /> locations may not be included in the scope of work and that separate pricing is requested for the <br /> performing the horizontal bore locations only. The proposed boring locations and corresponding <br /> depths are indicated below: <br /> BORE AND JACK BORING DEPTH (ft) <br /> LOCATIONS <br /> W2.2A 20 <br /> W2.2B 20 <br /> W2.3A 20 <br /> W2.3B 20 <br /> W2.56* 30 <br /> W2.5C* 30 <br /> S 1.2A 20 <br /> S 1.2B 20 <br /> S1.2C 20 <br /> S1.2D 20 <br /> S1.4A 20 <br /> S1.4B 20 <br /> S3.3A 25 <br /> S3.3B 25 <br /> S3.4A 20 <br /> S3.4B 20 <br /> S3.5A 20 <br /> S3.5B 20 <br /> S3.7A 20 <br /> S3.7B 20 <br /> HORIZONTAL BORE BORING DEPTH (ft) <br /> LOCATIONS <br /> W2.5A 30 <br /> W2.5B* 30 <br /> W2.5C* 30 <br /> W2.6A 35 <br /> W2.7A 25 <br /> W2.76 25 <br /> *indicates overlap locations for the bore/jack and horizontal drilling locations <br /> Responsive a Resourceful a Reliable 2 <br />