Browse
Search
Agenda - 12-11-2012 - 5j
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2012
>
Agenda - 12-11-2012 - Regular Mtg.
>
Agenda - 12-11-2012 - 5j
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2015 3:24:05 PM
Creation date
12/7/2012 11:50:58 AM
Metadata
Fields
Template:
BOCC
Date
12/11/2012
Meeting Type
Regular Meeting
Document Type
Agenda
Agenda Item
5j
Document Relationships
Minutes 12-11-2012
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14 <br /> AutoQuote 12.1 <br /> 2306 Scanner <br /> 2307 <br /> 2321 ( 1 ) *Three TruckLite LED#80251 C lights installed in center of module ceiling 684.68 684.68 <br /> 2324 ( 1 ) Switch on EMT switch panel and switch ... N/C <br /> 2325 ( 1 ) ...at side entry door. N/C <br /> 2328 ( 1 ) Timer"check out feature"(wired hot) 0-15 minutes installed at curbside door. 218.20 218.20 <br /> 2329 ( 1 ) `Activation by Shoreline power.See# 2510 for Battery Conditioners. <br /> 2331 ( 1 ) TruckLite LEDs#80162C EMT ("Standard" in action area) N/C <br /> 2347 <br /> 2349 ( 1 ) 4 white high/low intensity 7-inch dome lights mounted in ceiling on streetside N/C <br /> 2350 ( 1 ) 4 white high/low intensity 7-inch dome lights mounted in ceiling on curbside N/C <br /> 2354 ( 1 ) « Replace 8 standard dome lights with Whelen 8"LED dome lights. 837.84 837.84 <br /> 2366 ( 1 ) ` All ceiling lights to operate with two switches(one for streetside&one for curbside lights). <br /> 2377 ( 1 ) ' Install a switch by the curbside rear entry door to disable the rear scene lights. 194.03 194.03 <br /> 2381 ( 1 ) 'Clock,8" battery pwr w/second hand Location: over rear entry doors 88.25 88.25 <br /> 2399 ( 1 ) `Streamlight Light Box(SL-90) Rechargeable(pr ea) orange color 282.67 282.67 <br /> 2401 ( 1 ) `Streamlight "Stinger HP" (price each) 269.37 269.37 <br /> 2402 *Streamlight 12 VDC charger base to be mounted in: (SL-90)behind driver's seat in cab <br /> 2403 <br /> 2404 CUSTOMER NOTES/SPECIAL REQUESTS <br /> 2405 Mount the Stinger HP on the forward wall of the(R2)rear curbside compartment. 0.00 <br /> 2409 Supply&install an Engel EMS(#MD14F) refrigerator at the front bulkhead below 915.38 <br /> 2410 the counter at the pass-thru window. The refrigerator shall be installed on an 0.00 <br /> 2411 Engel slide lock plate and slide#TSL17 which shall be secured to the floor. Fabricate 0.00 <br /> 2412 and install a guard over the plug and controls. 0.00 <br /> 2413 Ref. line 2231:the 12VDC outlets will work off module power or shoreline power 0.00 <br /> 2414 alone. 0.00 <br /> 2415 Ref. line#2239:the buzzer shall activate when an entry door or compartment door 0.00 <br /> 2416 is open and chassis is placed in gear. 0.00 <br /> 2419 <br /> 2420 125 VAC ELECTRICAL: STANDARD SPECIFICATIONS <br /> 2421 <br /> 2422 Location for each 125 VAC duplex receptacle(interior to be lighted;exterior to be weatherproof): <br /> 2423 ( 1 ) two gang aft EMT panel "Standard" N/C <br /> 2424 ( 1 ) lower section of the R-4 ALS cabinet "Standard" N/C <br /> 2425 ( 1 ) below the pass-thru window on curbside wall 175.74 175.74 <br /> 2426 ( 1 ) on right side of cab console 175.74 175.74 <br /> 2431 GFI circuit breaker box to be located: mounted in GFI box in electrical panel N/C <br /> 2432 First GFI circuit breaker to be wired to: the engine block heater N/C <br /> 2433 Second GFI circuit breaker wired to: the 125V electrical system N/C <br /> 2436 Note: A 30 amp GFI circuit breaker must be used when a dual-voltage A/C system is <br /> 2437 selected. This circuit breaker must be dedicated to the dual-voltage A/C system and <br /> 2438 can NOT be used for anything else. Does this advisory apply to this order? YES <br /> 2439 <br /> 2446 <br /> 2447 SHORELINE OPTIONS Wholesale Extended <br /> 2448 Price Price <br /> 2455 ( 1 ) *Substitution: Kussmaul Super 30 amp Auto-Eject Shoreline Plug with 583.88 583.88 <br /> 2456 t waterproof cover and female input adapter(in lieu of"std"Shoreline Plug) <br /> 2460 'Specify color for Auto-Eject spring loaded cover: white N/C <br /> 2461 <br /> 2462 Additional Shorelines: <br /> 2463 A 30 amp Shoreline may be selected if a dual-voltage A/C system <br /> 2464 is selected. This Shoreline should be dedicated to the dual-voltage A/C system and <br /> 2465 can NOT be used for anything else. Does this advisory apply to this order? YES <br /> 2466 <br /> 2473 ( 1 ) 'Additional Kussmaul Super 30 amp Auto-Eject Shoreline Plug with 824.82 824.82 <br /> 2474 " waterproof cover and female Input Adapter <br /> Page 12 9/4/2012 1:41 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.