Browse
Search
Agenda - 11-19-2012 - C2
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2012
>
Agenda - 11-19-2012 - Quarterly Public Hearing - Late
>
Agenda - 11-19-2012 - C2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2013 4:58:48 PM
Creation date
11/12/2012 10:29:53 AM
Metadata
Fields
Template:
BOCC
Date
11/19/2012
Meeting Type
Public Hearing
Document Type
Agenda
Agenda Item
C2
Document Relationships
Minutes 11-19-2012
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Article 6: Development Standards <br />Section 6.11: Outdoor Lighting <br />(c) The plan shall include a detailed description of the luminaries, including <br />lamps, poles or other supports and shielding devices, which may be <br />provided as catalogue illustrations and product specifications from the <br />manufacturer. As part of this requirement, all lighting plans shall contain <br />inset drawings of all proposed lighting fixtures including any directional <br />controls (i.e. shields, reflectors, refractors, etc.) that will aim and limit the <br />angle of illumination. The lighting detail shall also show the vertical <br />angle of illumination for all proposed fixtures that will be used to <br />determine the required shielding angle; <br />(d) A lighting plan shall delineate the horizontal position of all lighting fixtures <br />proposed for a parcel of property; and <br />(e) Photometric data, such as that furnished by the manufacturer, showing <br />the angle of light emission and lumen output shall be required. An <br />example of a photometric plan is as follows: <br />Figure 6.11.5.B.2.e: Lighting Plan Standards, Photometric Plan <br />C1 <br />20.7 19.2 19.9 20.3 18.7 21.7 <br />In this example, the proposed light pole generates the specific lumen levels on the property. <br />Staff will be responsible for utilizing this data to verify the compliance of the fixture within the <br />provisions of this Ordinance. <br />(f) Foot - candle data shall also be required for all proposed outdoor lights. <br />An example of the data necessary to comply with this requirement is as <br />follows: <br />Orange County, North Carolina — Unified Development Ordinance Page 6 -70 <br />
The URL can be used to link to this page
Your browser does not support the video tag.