Browse
Search
2012-373 EMS - Sunguard Public Secotr Inc for CAD Replacement $589,875
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2012
>
2012-373 EMS - Sunguard Public Secotr Inc for CAD Replacement $589,875
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2015 8:04:00 AM
Creation date
10/5/2012 3:25:34 PM
Metadata
Fields
Template:
BOCC
Date
10/2/2012
Meeting Type
Regular Meeting
Document Type
Contract
Agenda Item
7b
Document Relationships
2012-373 S EMS - Sungard Public Sector Inc for CAD Replacement $589,875.00
(Linked From)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2012
2015-536-E Tax-EMS - Zoll Data Systems, Inc. - Addendum to master contract for autoattach for scanned documents software addition
(Linked From)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2015
2015-538-E Tax-EMS - Zoll Data Systems, Inc. - Addendum to master contract for autoattach for scanned documents software addition
(Linked From)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2015
2015-544-E Tax-ES - Zoll Data Systems, Inc. - Addendum to master contract - scanned documents software addition
(Linked From)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Long Description:The Message Switch software includes a query interface from the SunGard application for workstation-to- <br /> Workstation messaging. Secondarily, it supports State/NCIC queries from the Data Entry window. Responses from the State <br /> come back to the user in the message queue. <br /> The Message Switch must run on Windows 2000 Server or higher, not a Workstation,due to Client Access License limitations of <br /> the workstation. The Message Switch supports basic queries. <br /> NOTE:Any State/NCIC data entry functions must be performed with state supplied software or technology. <br /> ---------------------------------------------------------------------------------------------------------------- <br /> Part Number:MCT-SWI-S2S-T14 <br /> Description:SWITCH TO SWITCH <br /> Long Description:The S2S(Switch to Switch)module is designed to route Message Switch traffic,including car to car messages, <br /> RMS Name queries,and RMS Vehicle queries between two or more independent Message Switch applications. This feature allows <br /> for external agency returns of local data with a single query. With S2S in place,an agency running NCIC/State queries will also <br /> query connected agency(s)'RMS database for matching Names and Vehicles and return those results as an external response <br /> message. <br /> This product requires TCP/IP connectivity between the respective Customers. This connectivity is the responsibility of each <br /> participating Customer. If a non-dedicated TCP/IP connection is chosen(i.e. internet connectivity),then a VPN solution is highly <br /> recommended for security reasons. All firewall and VPN connectivity between the Customers are the responsibility of the <br /> participating Customers. <br /> ---------------------------------------------------------------------------------------------------------------- <br /> Part Number:MCT-MIS-T4 <br /> Description: LAN CLIENT LICENSE FOR MESSAGE SWITCH <br /> Long Description:A client license is required for each CAD, RMS or JMS workstation connected to the Customer's LAN or WAN to <br /> access SunGard Public Sector's Message Switch. <br /> The Message Switch Client provides the following functions: <br /> Workstation-to-workstation messaging <br /> Mobile-to-workstation messaging(if mobile applications are licensed) <br /> SunGard Public Sector's standard State/NCIC queries <br /> ---------------------------------------------------------------------------------------------------------------- <br /> Part Number:CAD-INT-FIREHOUSE <br /> Description: FIREHOUSE RMS INTERFACE <br /> Long Description:The Firehouse interface allows CAD to provide Firehouse software a one direction transfer of data for call <br /> incident number, units and associated times. SunGard Public Sector's CAD creates tables within a specified directory which <br /> Firehouse may then import into their application. Firehouse application software does not provide any data to CAD. <br /> ---------------------------------------------------------------------------------------------------------------- <br /> Part Number:CAD-INT-EMSCH <br /> Description:ZOLL PATIENT REPT INTERFACE <br /> Long Description:The Zoll interface allows OSSI CAD to send event data to the Zoll Charts Patient Care Reporting System. OSSI <br /> CAD sends specific data elements to Zoll as they occur throughout the life of the CAD event. This process gives EMS Charts <br /> access to the most current CAD data relating to an event. Pricing provided by SunGard is applicable to SunGard Data Systems <br /> only and specifically does not include any pricing proposed by any additional 3rd parties to implement the proposed solution. <br /> ---------------------------------------------------------------------------------------------------------------- <br /> Part Number:CAD-RR-T4 <br /> Description: RIP AND RUN PRINTING/FAXING MODULE <br /> Long Description:The Rip and Run Module allows for remote call notification reports(network printing,faxing,and email)at <br /> Fire/EMS stations. When units are dispatched,the station receives a Dispatch Report that includes(location, nature,x-streets,call <br /> taker notes, premise alerts,street notes,medical priority level,etc.).The customer can configure Rip and Run Module to send one <br /> Dispatch Report to each responding station or a Dispatch Report for each responding unit. When all units clear the call,each <br /> station dispatched will automatically receive a CAD Event Report containing the full radio and event log for the call. <br /> For printing,the Rip and Run Module requires each printer to be a network laser printer compatible with Windows 2000 or higher <br /> OS. Faxing requires a dedicated phone line,fax machine,and WinXP/WIN2003 faxing services. Emailing requires that the <br /> machine running the Rip and Run application be configured by the customer for Email support. Stations can be configured for <br /> either network printing,faxing or emailed reports. <br /> ---------------------------------------------------------------------------------------------------------------- <br /> Part Number:CAD-TONE-T4 <br /> Description:STATION TONING MODULE <br /> Long Description:The Station Toning Module is integrated with the agency's choice of a Zetron Model 25 or Model 26 encoder or <br /> Orbacom. When units are dispatched,CAD passes the key sequence codes to the unit that activates the paging system. <br /> The Customer must purchase and install the Zetron or Orbacom hardware equipment. <br /> ---------------------------------------------------------------------------------------------------------------- <br /> Part Number:CAD-PQA-MED-T4 <br /> Description:MEDICAL PROQA INTERFACE <br /> Long Description:SunGard Public Sector has developed an interface to ProQA's windows version of Medical Dispatch. SunGard <br /> Public Sector does not include the license fees for the ProQA software because the Customer normally acquires ProQA application <br /> Page 17 of 30 <br /> SPS License 7/1/2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.