Browse
Search
Agenda - 01-24-2012 - 8c
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2012
>
Agenda - 01-24-2012 - Regular Mtg.
>
Agenda - 01-24-2012 - 8c
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2015 3:00:41 PM
Creation date
1/20/2012 2:41:08 PM
Metadata
Fields
Template:
BOCC
Date
1/24/2012
Meeting Type
Regular Meeting
Document Type
Agenda
Agenda Item
8c
Document Relationships
Minutes 01-24-2012
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6 <br /> Electrical <br /> The electrical service is adequately sized for the facility, though quantity and <br /> placement of devices does not meet modern expectations in many spaces. <br /> Improvements may be required for space that remains. <br /> Metal halide lighting in the gymnasium would be replaced with compact <br /> fluorescent bulbs and ballasts for energy efficiency. Most other lighting in the <br /> facility has previously been upgraded to T-8 fluorescent bulbs and ballasts. <br /> Plumbing <br /> Most existing plumbing fixtures, water supply lines, and wastewater lines would <br /> be removed as part of the process of removing the north and south wings, as this <br /> would include removal of the main restrooms. The existing well and septic <br /> systems would be left in place. New restrooms would be constructed to replace <br /> the existing central restrooms that would be removed. Existing water supply <br /> lines, and wastewater lines, which run under the remaining slab, would be left in <br /> place. <br /> Roof <br /> The existing roof was installed in 1995 with a ten-year warranty, and so is well <br /> past its expected useful life. Some roof sectors on the portions of the building <br /> that would remain have decking that has tested positive for the presence of <br /> asbestos, although the-decking on the gymnasium and dining hall did not. <br /> Abatement would be required for approximately 21,000 square feet of roof <br /> decking. Although encapsulation is possible, leaving any asbestos-containing <br /> materials or products in place is not recommended. <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.