Browse
Search
Orange County NC RaCEsm Results
OrangeCountyNC
>
BOCC Archives
>
Reports
>
Orange County NC RaCEsm Results
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2012 9:44:51 AM
Creation date
1/3/2012 10:10:51 AM
Metadata
Fields
Template:
BOCC
Date
11/17/2011
Meeting Type
Regular Meeting
Document Type
Others
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C unications <br />Orange RaCE Test Report <br />and then initiates stalk-out message. The talk-out message is received at the mobile <br />unit, recorded, and analyzed. The location of the talk-out DAQ measurement is <br />established as the latitude and longitude of the mobile unit when the talk out message <br />began. In this manner, both paths (talk-in and talk-out) are evaluated in RaCE testing. <br />5.5.2 Passed/Failed DAQ Test Sample <br />A passed test sample is one in which a message is received and equal to or exceeds the <br />established DAQ threshold value. A failed test sample is one in which a test sample <br />message is initiated and either no reply message is received within the test timeout or the <br />received message is below the established DAQ threshold value. Test sample result <br />locations are established based on the location of the mobile at the start of the test <br />message. Regardless of the pass or fail result, the actual audio file is retained as part of <br />the test file both for after-the-fact confirmation, and also for any future analysis that might <br />be indicated. <br />5.5.3 Received Signal Strength Indicator (RSSI) Test Samples <br />Received Signal Strength Indicator (or Indication): A measurement in dBm that <br />represents the strength of the incoming (received) signal ih a receiver. <br />The mobile test unit has two additional auxiliary receivers and antennas to perform RSSI <br />measurements. During testing, the RSSI receivers scan through the stored frequency <br />table and collect samples based upon the analog-to-digital conversion of the voltage <br />present on the automatic gain control line from the receiver. These samples are <br />collected continuously except during the talk-in DAO test transmission. Ten samples are <br />collected per frequency at an average rate of 57 samples per second and then the <br />receiver scans to the next frequency. The receivers have been programmed to allow 50 <br />milliseconds to tune to the next frequency on the scan list and settle before beginning the <br />series of RSSI measurements at the new frequency. See FIGURE 5-1 below. The <br />dynamic range of the ICOM receiver is -55 dBm to -120 dBm with a 1 dB resolution. The <br />median value of a frequency's samples that were collected during the talk-out message is <br />used for analysis and display. This data was post-processed and included in the test <br />results section of this report. <br />f,1 f, 3 f~ 9 f21 fZ 3 fz9 <br />* f, 2 ~ ~, f, 10 ? fZ 2 ~ ~. f210 <br />••• I I I I I••• <br />Sec <br />50 msec <br />5.5.4 Passed/Failed RSSI Test Sample <br />A passed RSSI test sample is one in which the recorded signal level of the sample is <br />equal to or exceeds the established CPC threshold. A failed RSSI test. sample is one in <br />which the recorded signal level of the sample is below the established CPC threshold. <br />Test sample result locations are established based on the location of the mobile at the <br />start of the test message. <br />- 11 - $-tiv1'~ .; ..~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.