Browse
Search
ORD-2005-024 - Orange County Flood Damage Prevention Ordinance Amendments
OrangeCountyNC
>
Board of County Commissioners
>
Ordinances
>
Ordinance 2000-2009
>
2005
>
ORD-2005-024 - Orange County Flood Damage Prevention Ordinance Amendments
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2013 11:59:57 AM
Creation date
10/22/2010 3:21:41 PM
Metadata
Fields
Template:
BOCC
Date
5/23/2005
Meeting Type
Public Hearing
Document Type
Ordinance
Agenda Item
C.1
Document Relationships
Agenda - 05-23-2005-c1
(Linked To)
Path:
\Board of County Commissioners\BOCC Agendas\2000's\2005\Agenda - 05-23-2005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
05/12/2005 28 <br />(Ord. of 8 -28 -1995, § 5.1, eff. 8 -28 -1995) <br />Sec. 42 -92. Specific standards. <br />In all areas ef speeial fleed hazard SFHAs where BFE data has been provided, as set forth in <br />Section 42 -37 or 42 -69, the following provisions are required: <br />1. Residential Construction. New construction or substantial improvement of any residential <br />structure (including manufactured homes) shall have the lewest floor reference level, <br />including basement, elevated no lower than two feet above the base flood elevation the <br />regulatory flood protection elevation, as defined in Article 2 of this Ordinance. Should <br />solid foundation perimeter walls be used to elevate a structure, opening sufficient to <br />automatically facilitate equalization of hydrostatic flood forces on exterior walls the <br />urAmpeded movements of fleedwat shall be provided pursuant to Section 42 -. <br />2. Non - Residential Construction. New construction or substantial improvement of any <br />commercial, industrial, or other non - residential structure <br />shall have the lowest flee reference level, including basement, elevated no lower than #tee <br />feet above the base fleed eley tie the regulatory flood protection elevation. Structures <br />located in A, AO, AE and Al -30 Zones may be flood proofed no lower than two feet above <br />the level of the base flood elevation in lieu of elevation provided that all areas of the structure <br />below the required flood protection elevation are watertight with walls substantially <br />impermeable to the passage of water, using structural components having the capability of <br />resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A North Carolina <br />licensed Professional Engineer or Architect shall certify that the standards of this subsection <br />are satisfied. Such certification shall be provided to the official as set forth in Section 42 -68. <br />3. Manufactured Homes. <br />a. New or replacement manufactured homes shall be elevated so that the reference <br />level of the manufactured home is no lower than the regulatory flood protection <br />elevation. <br />Ci:- .E;;��:�;,�, ?xttil�e �'iar!i; � C3it����E�;`',.��T >','>C?3 ✓: �!c }�is azrir!g,.'_'�sv 23�.Ftc;a_'�.�;?,,+sc:d t .xiiiaza!•c: ,�! ? ?.:f; <br />*20101 "Wor, <br />RMIRRIKIWIS <br />Ci:- .E;;��:�;,�, ?xttil�e �'iar!i; � C3it����E�;`',.��T >','>C?3 ✓: �!c }�is azrir!g,.'_'�sv 23�.Ftc;a_'�.�;?,,+sc:d t .xiiiaza!•c: ,�! ? ?.:f; <br />
The URL can be used to link to this page
Your browser does not support the video tag.