Orange County NC Website
._~~ --•^r-~••7 ..v.wv W1~,uu6'UOft R 069t7n. MateC <br />~~~.. •~~~.a~~a~~~~, are to oe ~n stnct accardancs with spedfications of the American Railway Engineering Association and requirements pt Norfc <br />Southern Corporation. Origins! and six Copies at this form shall be submitted, accompanied by six prints of a drawing showing plan, eltyaiic <br />section of crossing from field survey, location in respect to Milepost. width of Railroad's Right of Way, width of Public Right of'YVay, Iocatir <br />of adjacent structures affecting crossing, and ail information required in Flgures t and 2 of A.R.E~1. Specifications, Part 5 Pipelines. It Wnnelir <br />is necessary details of sheeting and method of supporting tracks or driving tunnel must be shown. <br />t2. Correct name of Applicant: County of Orange ~ - - 19 <br />13. Post Office address: P • 0. Box 8181 , Hillsborough, NC <br />t a. Location: 3 33 3 0--- ~ K, ii (direction] from nearest R.R. Milepost H- 3 6 <br />15. Nearest city or town: Mebane County: Orange State-siC <br />t 6. Within limits of public highway, name: Redman Crossing Fed•State-County No.: s . R . 13 9 9 <br />17. Witt temporary track support or rip rapping be required? ( ]Yes (X ] No • explain Bore and Jack a c r o s s <br />entire R/W <br />18. Are there any wires. poles or obstruCions to be relocated? ( ]Yes (X] No Temperature <br />t 9. Product to be conveyed- ~ a n i t a r y Sewer Flammable? Yea Amb l e n t <br />• ( ] ~C ] No Temperature <br />20. Maximum working pressure: (ps,) Feld test pressure: ~ (psr) Type of test <br />2t. Locationotshut•oftvalves• at edctes of Railroad R/W <br />22. PIPE SPECIFlCATIONS <br />Material <br />CARRIER PIPE <br />CASING PIPE <br />ER Weld Steel Pipe <br />Material specifications and grade <br />Minimum Yield Strenght I;ps~) of malaria! <br />Milt test pressure (pst) <br />Inside diameter <br />Outside diameter <br />Wall thickness <br />Type of seam <br />Laying lengths <br />Type of joints <br />Total length within Railroad right of way <br />VENTS -number: 0 size: <br />SEALS -both ends: concrete one end: <br />BURY•• base of rail to top of casing: 9 ft. 0 in. <br />BURY • (not beneath tracfcs): 5 tt. 9 in. <br />BURY • (roadway ditches): 3 R 0 in. <br />CATHODIC PROTECTION - ( ]Yes (X] No <br />Ductile Tron <br />ANSI A21.51 <br />42,000 °psi <br />350 psi <br />3.46" <br />3.96" <br />0.25" <br />N/A <br />18' <br />Push-On <br />230' .. <br />height above ground: ' <br />API 5L <br />1530 psi <br />920 psi <br />8.25" <br />8.625" <br />0.188" <br />Field weld all <br />'ar 20' <br />field weld all <br />230' <br /> <br />PROTECTIVE COATING - ( j Yss (~(] No Give description • <br />23. Specify type, size, and spacing of insulator or supports: carrier pipe- sttppar~ed by "spiders" at <br />9.0' intervals - <br />2a. Define any special specifications of the pipeline: see above • <br />25. Method of installation: Bore and jack casing pipe <br />If application is approved, applicant agrees to reimburse the Railroad for any cost incurred by the Railroad incident to installation, <br />maintenance, and/or supervision necessitated by this pipeline installation. and further agrees to assume all liabiltiry for accidents or <br />injuries which arise as a result of this installaton. ~ /~ n <br />~- ~ 9~ <br />(ate) <br />Tohn Link <br />M, <br />(sEE SAMPLE ORAWJNG (EshlbR A), and SAMPLE SNEJT (E~rhlbft 8), atbehed) <br />