Browse
Search
Agenda - 11-23-2009 - C2
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2009
>
Agenda - 11-23-2009
>
Agenda - 11-23-2009 - C2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2013 2:17:32 PM
Creation date
11/18/2009 4:24:59 PM
Metadata
Fields
Template:
BOCC
Date
11/23/2009
Meeting Type
Public Hearing
Document Type
Agenda
Agenda Item
c2
Document Relationships
Minutes - 20091123 QPH
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2009
ORD-2009-179 - Sign Ordinance Amendments - Outdoor Advertising Signs (Billboards)
(Linked From)
Path:
\Board of County Commissioners\Ordinances\Ordinance 2000-2009\2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
41 <br />A final problem is related to the swimming pool /clubhouse facility. The <br />pool does not include an area large enough to serve the projected 600+ <br />residents that would ultimately reside in the development. The pool is only <br />slightly larger than 1,000 sq. feet in area, and .a pool of 2,000 -2,500 square <br />feet is more desirable to serve the anticipated number of residents. Clubhouse <br />activities and plans also need to be stated /designated clearly so that specific <br />uses of the facility will be known. <br />- In addition to the criteria set forth for rezoning, the applicant must <br />also comply with additional standards which apply to Planned Developments. <br />Article 7 of the Zoning ordinance contains these standards and indicates the <br />purpose for such a district designation - the establishment, for specialized <br />purposes, where tracts suitable in location, area and character for the uses <br />and structures proposed are to be planned and developed on a unified basis. <br />Section 7.14 of the Zoning Ordinance contains those standards which apply <br />specifically to Planned Development - housing designations such as that proposed. <br />The Planning Staff has reviewed the site plan submitted by the applicant for <br />compliance with these standards and has the following comments: <br />(1). A storri drainage plan for the development must be prepared, showing <br />how drainage will be handled in relation to proposed building. and parking <br />areas. <br />(2). <br />Recreational plans must be revised to delete the access easement <br />serving jiilcwood Subdivision -Phase II. Recalculation of those pedestrian paths <br />included as part of the recreation system must be provided and those paths <br />designated <br />on the plan. The proposed pool must be enlarged to serve the <br />population <br />projected in the development, and plans for the clubhouse provided, <br />showing the use of interior spaces. <br />(3). <br />Proposed sewage collection plans must be revised, where necessary, <br />to address <br />the following: <br />A. Sewer mains are located to close• to buildings in some <br />instances. These must be relocated and easements designated if the <br />lines . are to be dedicated to Hillsborough for maintenance. A 30' <br />easement is to be provided for maintenance. <br />D. Connections to three existing manholes are shown. The engineer <br />should provide invert elevations which indicate that access to <br />these manholes is accessible. <br />C. Several lines appear to be running uphill. The engineer should <br />provide an indication that sewer lines will be located at a <br />{a• <br />sufficient depth to attain a gravity flow. <br />D. An additional manhole is needed in one line which makes a bend <br />or curve. <br />(4). <br />Proposed water distribution plans must be revised, where necessary, <br />to address <br />the following:: <br />A. Extend the 12 -inch crater line in the proposed Oakdale Drive <br />Extension as shown on the plans for Wildwood Subdivision. Phase II <br />to connect with the six -inch line running through Hampton Downs to <br />form a loop system. The six -inch line proposed for Walter Clarke <br />Drive may then be deleted. <br />B. Two additional hydrants are required, and two others must be <br />relocated to provide a total of five hydrants, all more or less <br />equally spaced 500' apart. <br />C. All dead end two -inch water lines must have blow -off valves to <br />clear stagnant water. <br />
The URL can be used to link to this page
Your browser does not support the video tag.