42 <br /> structural status, is considered an enclosure and requires <br /> hydrostatic openings as outlined above to comply with this <br /> Ordinance. <br /> b. The enclosed areas shall be used solely for parking of vehicles, building <br /> access, or storage. Access to the enclosed area shall be the minimum <br /> necessary to allow for parking of vehicles (garage door) or limited storage <br /> of maintenance equipment used in connection with the premises (standard <br /> exterior door) or entry to the living area(stairway or elevator). The interior <br /> portion of such enclosed area shall not be partitioned or finished into <br /> separate rooms. <br /> 7. Temporary structures. Prior to the issuance of a floodplain development permit for a <br /> temporary structure, the following requirements shall be met: <br /> a. Applicants shall submit to the Floodplain Administrator a plan for <br /> the removal of such structure(s) in the event of a hurricane or flash flood <br /> warning notification. The plan shall include the following information: <br /> i. A specified time period for which the temporary use will be <br /> permitted; <br /> ii. The name, address, and phone number of the individual <br /> responsible for the removal of the temporary structure., <br /> iii. The time frame prior to the event at which a structure will be <br /> removed(i.e.,minimum of seventy-two (72)hours before <br /> landfall of a hurricane or immediately upon flood warning <br /> notification); <br /> iv. A copy of the contract or other suitable instrument with a <br /> trucking company to ensure the availability of removal <br /> equipment when needed; and <br /> v. Designation, accompanied by documentation, of a location <br /> outside the SFHA to which the temporary structure will be <br /> moved. <br /> b. The above information shall be submitted in writing to the Floodplain <br /> Administrator for review and written approval. <br /> 8. Accessory Structures. When accessory structures (sheds, detached garages, etc.) are <br /> to be placed within a SFHA, the following criteria shall be met: <br /> a. Accessory structures shall not be used for human habitation (including <br /> work, sleeping, living, cooking or restroom areas); <br /> b. Accessory structures shall be designed to have low flood damage potential; <br />